ACI Northwest Blog: Posts Tagged ‘Geothermal Installation’

Components of a Geothermal Heating System: A Guide from ACI Northwest

Wednesday, October 12th, 2011

A geothermal heat system in your Hayden home has three basic components and some add-on ones as well.

Its most distinguishing feature is the ground loops. The most common is the “closed” ground loop system, which is a series of pipes that are buried underground. These pipes contain a heat transfer fluid, comprised of antifreeze and water. This fluid absorbs heat from the ground and carries it to the home. This fluid also absorbs heat from the house and sends it into the ground to keep the home cool.

Examples of closed loop systems include the horizontal closed loop, which can be used in larger parcels of land (over an acre for example). The loops are placed typically placed horizontally 6-to-10 feet below the surface. A vertical closed loop design is recommended for smaller parcels of land and loops are often buried vertically approximately 20 feet underground. Other types of ground loop designs use well water to transfer heat in an open loop configuration, or have a closed loop submerged underwater in a pond or lake.

The next component is the heat pump, which draws the fluid from the ground loop. In a heat pump, heat energy is exchanged with the ground to heat or cool the home. In the heating mode, fluid warmed from underground flows through the heat pump. A fan blows across the pipe warmed by the fluid. Because the fluid is much warmer than the air inside the heat pump, heat energy is released into the cooler air. The cool air is warmed and distributed inside the home. The process is reversed for cooling. Cool fluid in the pipe absorbs heat from the warm air inside the home. Once pumped underground, the excess heat in the fluid is absorbed by the cooler earth.

The final component is the air handling or distribution system. Here, a fan in the heat pump’s furnace blows air over a fan coil and the heated cooled air is distributed through the home’s ductwork. Some distribution systems are hydronic, where hot water is circulated through radiators or radiant floor heat tubing. This water absorbs heat from the heat pump and then distributed throughout the home.

In some homes, both a forced air and hydronic system, often referred to as a “hybrid system” work together.

Optional components include a heat pump “desuperheater,” which is used to help with domestic hot water heating. In warm weather, the desuperheater recovers some of the heat – that would otherwise be sent to the ground loop – to help produce hot water. In cold weather, some of the heat pump capacity may be diverted from space heating for the same purpose. Desuperheaters save approximately 25% on domestic water heating costs.

Another component is an auxiliary electric heater, which is built into the geothermal heat pump This auxiliary electric heat is installed to allow heating and cooling technicians to size – or resize – a home’s geothermal heat pump system to assist the system during the few coldest days of the year. Auxiliary electric heat is also an emergency backup heat source if there are any operational issues with the geothermal heat pump system.

If you have any questions about this system, talk to your local contractor.

Continue Reading

How Effective is Geothermal Heating? A Question From Cocolalla

Wednesday, October 5th, 2011

Geothermal heating is an efficient way to use the Earth’s natural resources to heat a building’s interior in Cocolalla. But is it an effective way? Of course.

Consider the cost of geothermal heating. Once you get past the initial installation costs of a geothermal heating system, which are higher than other conventional heating systems, its operating costs are much lower because of its use of a natural, renewable heat source – the Earth. If you plan to stay in your home for many years, a geothermal heating system will likely pay for itself because according to International Ground Source Heat Pump Association, geothermal operating efficiencies are 50-70% higher than other heating systems, which represents a substantial lowering of energy costs.

And according to a leading electric utility company, the cost of electricity for operating a geothermal heat pump is lower than any other heating system which includes natural gas, propane, and oil.

Beyond lower energy costs, geothermal heating leaves a smaller carbon footprint than other heating systems. According to the U.S. Environmental Protection Agency, carbon dioxide (CO2) emissions from the average U.S. home is 17%, most of which comes from burning fossil fuels for electricity. Geothermal uses natural heat from the ground and therefore uses 30-60% less energy than more conventional heating and cooling systems. Using less energy equals less carbon dioxide production.

A geothermal heating system is only as effective as the equipment used to deliver it throughout the building. The most common delivery method is through a ground source heat pump. This pump pulls the heat from the earth and distributes it. When properly installed and maintained, a ground source heat pump can last 15-20 years and provide an excellent source for heating – and cooling.

The components of a geothermal system also include a compressor, air handling unit, and duct system. When all are installed and maintained correctly, a geothermal heating system will be just as effective in heating a building’s interior as any other heating system. Just be sure you hire a qualified heating and cooling professional to install and service your geothermal heating system.

Continue Reading